PDUBHV10

Còn hàng

Tổng quan

Overview Tripp Lite’s Hot-swap PDU systems enable live-replacement of standard UPS systems for maintenance with no interruption of connected server or networking loads. Dual input power cables support PDU connection to separate Utility and UPS power sources. Manual transfer switch with lighted status indicators controls the source of power to connected equipment between Utility and UPS. Set the switch to UPS during normal operation and connected equipment will receive full-time conditioned power from the UPS. Set the switch to Utility to momentarily power connected equipment from the Utility line cord and bypass the UPS while the...

Overview

Tripp Lite’s Hot-swap PDU systems enable live-replacement of standard UPS systems for maintenance with no interruption of connected server or networking loads. Dual input power cables support PDU connection to separate Utility and UPS power sources. Manual transfer switch with lighted status indicators controls the source of power to connected equipment between Utility and UPS. Set the switch to UPS during normal operation and connected equipment will receive full-time conditioned power from the UPS. Set the switch to Utility to momentarily power connected equipment from the Utility line cord and bypass the UPS while the UPS system is removed and replaced with a fresh one. Once the new UPS is up and running with all data and electrical connections restored, set the switch back to the UPS setting to once again provide fully-conditioned UPS power to connected equipment.

Features

  • Tripp Lite Hot-swap PDU systems support live-replacement of standard UPS systems for maintenance with no interruption of connected server or networking loads
  • PDUBHV10 is universally compatible with any Tripp Lite or other brand of 200-240V UPS rated up to 1500VA with a C14 input cable option
  • 2U horizontal rackmount form factor compatible with 2 or 4 post racks
  • Supports space saving rear-post mounting in the same rack space as many Tripp Lite Rackmount UPS systems (select installations, see manual)
  • Pair of detachable PDU input cables connect to separate Utility and UPS power sources (2 C13-C14 interconnect cables included - user supplied alternate cabling supported)
  • 8 C13 outlets support critical networking loads in both Utility and UPS operating modes
  • One additional C13 pass-through outlet supports UPS input power cord
  • Dual input power cables support PDU connection to separate Utility and UPS power sources
  • Manual transfer switch with lighted status indicators controls the source of power to connected equipment between Utility and UPS
  • Set the switch to UPS during normal operation and connected equipment will receive full-time conditioned power from the UPS
  • Set the switch to Utility to bypass the UPS and provide connected equipment with unfiltered power directly from the Utility line cord while the UPS system is removed and replaced with a fresh one
  • Once the new UPS is up and running with all connections restored, set the switch back to the UPS setting to once again provide fully-conditioned UPS power to connected equipment

Package Includes

  • Hot-swap PDU System
  • 2U mounting brackets
  • Set of 2 C13-C14 interconnect cables
  • User manual with warranty information
OVERVIEW
PDU Type Hot-Swap
OUTPUT
Output Watt Capacity (Watts) 2300
Output Capacity Details 2.4kW (240V), 2.3kW (230V), 2.2kW (220V), 2.08kW (208V), 2.0kW (200V) / 10A total capacity
Frequency Compatibility 50 / 60 Hz
Output Receptacles (9) C13
Output Nominal Voltage 200; 208; 220; 230; 240
Overload Protection n/a
INPUT
PDU Input Voltage 200; 208; 220; 230; 240
Maximum Input Amps 10
Input Connection Type UTILITY & UPS inputs are available from separately labelled C14 inlets, compatible with included C13-C14 interconnect cables or with compatible user-supplied cabling
PDU Plug Type IEC-320 C14
Input Cord Length (m) 1.83
Input Phase Single-Phase
USER INTERFACE, ALERTS & CONTROLS
Front Panel LEDs Lighted indicators confirm UPS and Utility switch position and operating mode
Switches Manual 2 position transfer switch offers fast switching between UPS and Utility operating modes in less than 6 milliseconds
PHYSICAL
Minimum Required Rack Depth (cm) 21
Shipping Dimensions (hwd / cm) 25 x 57.8 x 24
Shipping Weight (kg) 5
Unit Dimensions (hwd / cm) 8.7 x 44 x 7.7
Unit Weight (kg) 3.5
Material of Construction Metal
Form Factors Supported 2U rackmount in 2 or 4 post racks
PDU Form Factor Horizontal (1U, 2U, etc)
ENVIRONMENTAL
Storage Temperature Range 5 to 122F (-15 to 50C)
Relative Humidity 5-95% non condensing
Operating Elevation (m) 0-3000
CERTIFICATIONS
TAA Compliant Option TAA Compliant Version Available - Order Tripp Lite PDUBHV10TAA
Certifications Tested to UL60950 (USA), CSA (Canada), CE (IEC60950)
WARRANTY
Product Warranty Period (Worldwide) 2-year limited warranty
Find Us On FaceBook