SMX1200XLHG

Còn hàng

Tổng quan

Overview The SMX1200XLHG SmartPro 230V 1kVA 750W CE/IEC 60601-1 Medical-Grade Line-Interactive UPS provides medical-grade battery backup and AC power protection against blackouts, brownouts, power surges and line noise that can damage electronics or destroy data. Ideal for backing up devices in patient-care vicinities, the SMX1200XLHG switches to battery mode in milliseconds to keep your critical equipment running long enough to save files and shut down safely with no data loss. It meets strict leakage requirements for medical equipment used in non-life-support applications. Featuring six C13 outlets and a 1.8-meter power cord with C14...

Overview

The SMX1200XLHG SmartPro 230V 1kVA 750W CE/IEC 60601-1 Medical-Grade Line-Interactive UPS provides medical-grade battery backup and AC power protection against blackouts, brownouts, power surges and line noise that can damage electronics or destroy data.

Ideal for backing up devices in patient-care vicinities, the SMX1200XLHG switches to battery mode in milliseconds to keep your critical equipment running long enough to save files and shut down safely with no data loss. It meets strict leakage requirements for medical equipment used in non-life-support applications. 

Featuring six C13 outlets and a 1.8-meter power cord with C14 input, the SMX1200XLHG has an internal battery that provides 27.5 minutes of support at half load and 11 minutes at full load. A built-in isolation transformer with Faraday shield offers full line isolation and removes common mode noise, while maintaining full AC surge suppression.

Automatic voltage regulation (AVR) maintains 230V nominal output over an input range of 155V to 274V without using battery power. EMI/RFI noise filtering improves your equipment’s performance and prevents damage. A 340-joule surge suppression rating protects your equipment from harmful power surges. With Tripp Lite’s included PowerAlert® software, the SMX1200XLHG enables safe unattended system shutdown and file saves in case of a prolonged power failure.

Features

Protects Mission-Critical Medical-Grade Equipment

  • Provides AC output for electrical equipment in patient-care vicinities
  • Meets strict leakage requirements for medical equipment
  • Factory-muted alarm can be restored to signal loss of utility power, low battery or overload
  • 6 IEC-320 C13 outlets
  • 1.8 m power cord with C14 input
  • 480-joule surge suppression rating


Reliable Battery Backup with Expandable Runtime

  • Supports half load up to 27.5 min. and full load up to 11 min.
  • Internal batteries designed for hot-swap field replacement
  • Expandable runtime with optional external battery packs, such as Tripp Lite’sBP36V15-2U
  • Cold-start capability enables turn-on in battery mode during blackouts


Built-In Isolation Transformer with Faraday Shield

  • Offers full line isolation and removes common mode noise while maintaining full AC surge suppression


Automatic Voltage Regulation(AVR)

  • Maintains 230V nominal output over input range of 155V–274V without using battery power


EMI/RFI Line Noise Filtering

  • Removes electromagnetic and radio frequency interference that can disrupt or damage equipment’s performance


LED Indicators

  • Front-panel LEDs indicate line power, battery power, overload, voltage regulation and battery status


Communication Ports

  • USB and DB9 ports combine with included PowerAlert software to monitor operating conditions, monitor AC power, and enable safe unattended system shutdown and file saves in case of a prolonged power failure
OUTPUT
Output Volt Amp Capacity (VA) 1000
Output Watt Capacity (Watts) 750
Nominal Output Voltage(s) Supported 220V; 230V; 240V
Nominal Voltage Details 230v nominal inverter output voltage
Frequency Compatibility 50 / 60 Hz
Frequency Compatibility Details Automatic frequency selection
Output Voltage Regulation (Line Mode) -18%, +8%
Output Receptacles (6) C13
Output AC Waveform (Battery Mode) PWM sine wave
INPUT
Rated input current (Maximum Load) 5A
Nominal Input Voltage(s) Supported 230V AC
UPS Input Connection Type C14 inlet
UPS Input Cord Length (ft.) 6 inch dongle, 16 gauge
UPS Input Cord Length (m) 1.83
Recommended Electrical Service 10A 230V
Voltage Compatibility (VAC) 230
Input Phase Single-Phase
BATTERY
Full Load Runtime (min.) 11 min. (750w)
Half Load Runtime (min.) 27.5 min. (375w)
Expandable Battery Runtime Supports extended runtime with optional BP36V15-2U(limit 1) and BP36V42-3U external battery pack(multi-pack compatible)
External Battery Pack Compatibility BP36V15-2U(limit 1); BP36V42-3U(multi-pack compatible); BP36V27-2US(multi-pack compatible)
DC System Voltage (VDC) 36
Battery Recharge Rate (Included Batteries) Less than 4.5 hours from 10% to 90%
Internal UPS Replacement Battery Cartridge RBC53
Battery Access Battery access door allows hot swap battery replacement without powering connected equipment off
Typical Battery Lifespan 3-6 years, depending on usage
Expandable Runtime Yes
VOLTAGE REGULATION
Voltage Regulation Description Line interactive UPS offers 2 boost levels of brownout correction and a single level of overvoltage adjustment to maintain usable, computer grade output without consuming battery power over an input voltage range of 155 to 274V AC.
Overvoltage Correction Input voltages between 245 and 274V AC are reduced by 9%
Undervoltage Correction Input voltages between 183 and 199 are boosted by 10%
Severe Undervoltage Correction Input voltages between 156 and 182 are boosted by 21%
USER INTERFACE, ALERTS & CONTROLS
Switches Yes, includes 2 front panel mounted push-button switches for system enable, self-test and alarm cancel functions
Audible Alarm Audible Alarm is factory muted for silent operation; Audible alarm can be restored to indicate power failure, overload conditions and Low Battery events using our Free Power Alert UPS management software.
LED Indicators 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating 340 joules
EMI / RFI AC Noise Suppression Yes
AC Suppression Response Time Instantaneous
PHYSICAL
Installation Form Factors Supported with Optional Accessories Wallmount(UPSWM - tower mounting kit)
Primary Form Factor Tower
UPS Power Module Dimensions (hwd, cm) 32.3 x 19 x 23.1
UPS Power Module Weight (kg) 20.7
UPS Shipping Dimensions (hwd / cm) 47 x 31 x 34
Shipping Weight (kg) 22
Cooling Method UPS cooling via rear-exit fan
UPS Housing Material PVC
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load) 252.2
Battery Mode BTU / Hr. (Full Load) 252.2
COMMUNICATIONS
Communications Interface USB; DB9 Serial
LINE / BATTERY TRANSFER
Transfer Time 2-4 milliseconds
Low Voltage Transfer to Battery Power (Setpoint) 155
High Voltage Transfer to Battery Power (Setpoint) 274
SPECIAL FEATURES
Grounding Lug Ground Potential Equalization Connector: POAG-S6/20
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
CERTIFICATIONS
UPS Certifications CE; Tested to UL60601-1 (medical grade)
WARRANTY
Product Warranty Period (International) 2-year limited warranty
Product Warranty Period (Mexico) 2-year limited warranty
Product Warranty Period (Puerto Rico) 2-year limited warranty
Find Us On FaceBook